Quick Calibration
Device |
Einstein™ |
Einstein Pro XL™ |
The printer calibration allows you to set up compensation coefficients to tune the accuracy of your printer.
1. Generate the L-shaped job in Live Build DLP as stated in Printer Calibration and send it for print.
2. After the L-shaped job is printed, clean it well and post-cure the model as required for the used material.
3. Measure the printed model as shown below using a caliper, see Tolerance List.
![]() |
![]() |
4. From the Home screen of the printer, navigate to Settings > Move and Calibration > Quick Calibration.
5. Enter the obtained X and Y values in the appropriate fields.
5. Press Save to confirm.
Tolerance List
Printer | Tolerance, um | L-shaped Model Dimensions Range, mm |
Einstein™ | 101 |
X: between 63.90 and 64.10 Y: between 39.90 and 40.10 |
Einstein Pro XL™ | 92 |
X: Between 63.91 and 64.09 Y: Between 39.91 and 40.09 |