Quick Calibration

Device
Einstein™
Einstein Pro XL™

The printer calibration allows you to set up compensation coefficients to tune the accuracy of your printer.

1. Generate the L-shaped job in Live Build DLP as stated in Printer Calibration and send it for print.

2. After the L-shaped job is printed, clean it well and post-cure the model as required for the used material.

3. Measure the printed model as shown below using a caliper, see Tolerance List.

l-shaped.png Untitled_design__1_.png

4. From the Home screen of the printer, navigate to Settings > Move and Calibration > Quick Calibration.

quick-calibration.PNG

5. Enter the obtained X and Y values in the appropriate fields.

5. Press Save to confirm.

Tolerance List

Printer Tolerance, um L-shaped Model Dimensions Range, mm
Einstein™ 101

X: between 63.90 and 64.10

Y: between 39.90 and 40.10

Einstein Pro XL™ 92

X: Between 63.91 and 64.09

Y: Between 39.91 and 40.09